Necessity of Purging
The
following problems can arise if air or other gases remain in the air
conditioning circuit. Be sure to perform purging the air conditioner
circuit with a vacuum before charging with refrigerant (R134a).
1. Pressure rise in the high pressure side
If
air remains in the air conditioner circuit, this disturbs the heat
exchange between refrigerant and air in the condenser. This causes
pressure to rise in the high pressure side (compressor side).
Refrigerant
gas is easily liquefied, but air cannot be liquefied and remains as a
gas in the condenser because the temperature at which air liquefies is
extremely low. Therefore, liquidation of the refrigerant gas in the
condenser decreases by the amount of air in the circuit, and the gas
pressure in the high pressure side increases accordingly.
2. Metal corrosion
If
air remains in the air conditioner circuit, a chemical reaction between
refrigerant and moisture in the air takes place, and as a result,
hydrochloric acid is produced. Hydrochloric aid corrodes metals such as
aluminum, copper and iron.
3. Plugging of the expansion valve by
moisture When high pressure refrigerant gas passes through the expansion
valve, gas pressure decreases and temperature drops. Moisture included
in high pressure refrigerant gas in the air conditioner circuit freezes
at the expansion valve orifice, plugging refrigerant flow.
Operation of the air conditioner becomes unstable and cooling efficiency lowers.