Here is the instruction show you guide on how to perform calibration of the EPC rear for FENDT 900 Vario COM III.
FENDT Fendias 2024 Diagnostic software
Calibration of depth control (8001)
Important: The following preparatory steps must be carried out.
Hand brake applied
-
lgnition ON
If fault messages are displayed, the faults must be confirmed one by one.
Press "ESC" to confirm the warning and fault messages displayed on the A007
instrument panel
Press "Return", the first main menu appears in the multiple display
Press "Return", the second main menu appears in the multiple display
Press one of the buttons repeatedly until the symbol (A) flashes
The second main menu appears in the multiple display
Press one of the buttons repeatedly until the symbol (A) flashes
Press "Return" to confirm
The rear power lift menu level appears on the multi-display.
Press one of the buttons repeatedly until the symbol (A) flashes
Press "Return" to confirm
Input code 8001
Press one of the buttons until the required number is displayed
Press "Return" to confirm
Rotate depth control to Pos. 10 (floating position)
Press "Return" to confirm
Slowly rotate depth control to the right
Slowly rotate depth control to the right
NOTE: If the depth control is rotated too quickly, an im-
age will appear.
Rotate depth control back slightly
https://www.car-auto-repair.com
If calibration is completed without errors,O.K.appears and the new sensor settings are saved.
NOTE: Settings are only transferred when the ignition key has been turned to "0" position.
(Wait for at least 15 seconds before switching on the ignition again!)
If incorrect values are detected or the conditions are not met, an message appearsERROR
8001 = calibration code
FXX = error code (see table)
NOTE: The fault code is displayed from end-of-line program (EOL) 7.60 onward (Autumn 2007)