H13-624_V5.5-ENU HCIP-Storage V5.5 Exam Questions
The H13-624_V5.5-ENU HCIP-Storage V5.5 exam is an essential step for IT professionals looking to excel in storage technology. Suppose you're looking for the easiest way to pass this challenging exam. In that case, PassQuestion offers a set of newly released H13-624_V5.5-ENU HCIP-Storage V5.5 Exam Questions which are designed to help you understand key concepts and practice with real-world scenarios, making the certification path much smoother. Utilizing PassQuestion H13-624_V5.5-ENU HCIP-Storage V5.5 Exam Questions can significantly enhance your preparation, ensuring you confidently approach the exam.
What is HCIP-Storage Certification?
Holding the HCIP-Storage certification proves you have an in-depth understanding of storage technologies such as flash storage and scale-out storage products. The certification focuses on various essential skills, including installation, commissioning, performance tuning, maintenance (O&M), and troubleshooting of storage devices. With storage becoming the backbone of IT infrastructure in enterprises, this certification helps professionals stay ahead by mastering advanced tools and concepts.
Target Audience for HCIP-Storage V5.5 Exam
If you're wondering whether this certification is the right fit, here's a quick breakdown of who benefits the most:
1. Aspiring Storage Engineers
Those who want to build a career in storage technology and need validation of their knowledge and skills.
2. Professionals Aiming to Achieve HCIP-Storage Certification
IT experts and engineers working in cloud computing, enterprise IT infrastructure, or storage who wish to advance their credentials.
3. Administrators of Storage Arrays
Professionals responsible for managing storage solutions in data centers, enterprises, or other IT environments.
Prerequisites for Taking the HCIP-Storage V5.5 Exam
Before sitting for the H13-624_V5.5-ENU exam, it's important to have a solid foundation in related areas. Here's what you need to know:
Basic Network Knowledge – Familiarity with networking principles is essential for understanding how storage solutions interact with other components.
Understanding of Computer Components – A clear grasp of hardware basics ensures smooth installation and troubleshooting.
Knowledge of Windows and Linux Operating Systems – As storage systems are frequently deployed in both environments, familiarity with these OS platforms is required.
HCIA-Storage Certification – While not mandatory, it is recommended to complete HCIA-Storage as it provides a fundamental knowledge base.
HCIP-Storage V5.5 Exam Structure and Key Details
Let's go over the basic structure of the H13-624_V5.5-ENU HCIP-Storage Exam to help you prepare better.
Huawei Certification: HCIP-Storage Certification
Exam Code: H13-624
Exam Name: HCIP-Storage
Language: English (ENU)
Question Types: Single Answer, Multiple Answer, True-False, and Fill in the Blanks
Exam Fees: $300 USD
Exam Duration: 90 minutes
Passing Score: 600 / 1000
Key Topics Covered in the HCIP-Storage V5.5 Exam
The exam thoroughly tests your knowledge of various storage technologies and processes. Below is the breakdown of the exam content:
1. Storage Technologies and Applications (50%)
This section covers the core principles of flash storage and scale-out storage. You’ll need to understand technical architectures, performance features, and practical applications of these technologies in enterprise environments.
2. Storage Product Deployment (15%)
It focuses on the installation and configuration of storage systems, including hardware and software setup. Familiarity with deployment tools and methodologies is crucial here.
3. Storage System Performance Tuning (15%)
Learn how to analyze and optimize performance using industry benchmarks and tools. You’ll encounter scenarios requiring solutions for bottleneck identification and tuning strategies.
4. Storage System O&M and Troubleshooting (20%)
This section assesses your ability to monitor, maintain, and troubleshoot storage systems. You’ll need expertise in using Huawei’s storage O&M tools to perform diagnostics, handle alarms, and resolve issues effectively.
View Online HCIP-Storage V5.5 H13-624_V5.5-ENU Free Questions
1. Which of the following statements about rollback to a HyperCDP object in Huawei storage systems is false?
A. A HyperCDP object can be used for rollback only when it is in the activated state.
B. For a source LUN that has multiple HyperCDP objects, multiple HyperCDP objects can be used for rollback at the same time.
C. To ensure data consistency, stop host services before rolling back to a HyperCDP object.
D. If the source LUN of a HyperCDP object is also the primary or secondary LUN of a remote replication pair, perform the rollback only after the status of the remote replication pair becomes "Split".
Answer: B
2. Which of the following statements about Huawei SmartQuota is false?
A. SmartQuota helps system administrators manage storage resource usage of resource users.
B. The resource usage of a single directory, user, or user group can be limited.
C. Alarms and events can be used to notify resource users of their resource usage.
D. SmartQuota can be configured in block and file storage.
Answer: D
3. Which of the following statements about the HyperReplication feature is false?
A. A pair establishes the data replication relationship between the primary and secondary LUNs.
B. A consistency group is a collection of pairs that have a service relationship with each other.
C. Data synchronization is the process of replicating data from the secondary LUN to the primary LUN.
D. Splitting is when data replication from the primary LUN to the secondary LUN is paused.
Answer: C
4. Which of the following cables is used to connect Huawei hybrid flash storage to another storage device?
A. Fibre Channel cable
B. SAS cable
C. Mini SAS HD cable
D. 10GE cable
Answer: C
5. Which of the following statements about Huawei SmartVirtualization is false?
A. It is compatible with mainstream heterogeneous storage systems, facilitating centralized planning and management of storage resources.
B. You can use the LUNs on a heterogeneous storage system without performing a full physical data mirroring, saving storage space.
C. Multiple functions, such as remote replication and snapshot, can be configured for the LUNs on a heterogeneous storage system.
D. A heterogeneous storage system is configurable using SmartVirtualization, which simplifies management.
Answer: D
6. Which of the following statements about the working principles of CIFS is true?
A. Before a sharing connection is established, a session is established, and then protocol negotiation is performed.
B. File operations can be performed only after a sharing connection is established.
C. Security authentication is performed in the protocol negotiation phase.
D. After file operations are complete, the server automatically disconnects the share from the client without a request from the client.
Answer: B
7. The active-active architecture of Huawei all-flash storage systems enables load balancing of high-concurrency transaction services. Which statements about this architecture are true? (Multiple choice)
A. I/Os are evenly distributed to all front-end ports for access load balancing.
B. I/Os are evenly distributed to all controllers for front-end load balancing.
C. All controllers process services, and LUNs are not owned by any controller, thus achieving load balancing among controllers.
D. Data is evenly distributed to all SSDs for load balancing.
Answer: ABCD
8. A bank uses a Huawei all-flash storage system to carry its critical services. Which of the following can ensure data reliability? (Multiple choice)
A. Dual mappings for directory metadata ensure logical redundancy of service data.
B. Local snapshots provide service data redundancy.
C. RAID 2.0+ and multiple copies provide local physical data redundancy.
D. Active-active, replication, and backup ensure data redundancy across sites.
Answer: ABCD
9. Which of the following statements about the principles of file system snapshots are true? (Multiple choice)
A. A file system snapshot is a point-in-time copy of a source file system.
B. Write operations affect the write performance of storage LUNs because snapshots are stored at new locations after being created.
C. Redirect-on-write (ROW) is the core technology for implementing file system snapshots.
D. After a file system snapshot is created, users of the file system can access the snapshot only after the snapshot directory is mounted again.
Answer: AC
10. An engineer needs to perform rollback using a snapshot to obtain source data from a past time point. Which of the following statements about this operation are false? (Multiple choice)
A. Data rollback using a snapshot fully replicates and restores the source data from a previous time point.
B. Data rollback using a snapshot can be completed in seconds.
C. If data is rolled back to a snapshot created at time point A, snapshots created after time point A are deleted.
D. If data is rolled back to a snapshot created at time point A, snapshots created after time point A are not deleted.
Answer: AC
11. Which of the following statements about remote replication consistency groups are true? (Multiple choice)
A. Users can only add remote replication pairs to a consistency group on the primary storage system.
B. Secondary LUNs of all remote replication pairs must be on the same remote storage system.
C. LUNS of different remote replication pairs in a consistency group can belong to different working controllers.
D. Remote replication pairs in a consistency group must work in the same replication mode.
Answer: ABCD
12. Which of the following are supported by the HyperReplication feature of Huawei all-flash storage systems? (Multiple choice)
A. Load balancing
B. Failover
C. Interoperability between entry-level and high-end storage devices
D. Consistency group
Answer: ABCD
13. When delivering a storage system, engineer A fails to detect LUNs by scanning on a Linux service host. Which of the following are possible causes of this? (Multiple choice)
A. The storage pool is faulty.
B. The link is faulty.
C. Zones are incorrectly configured.
D. No multipathing software is installed on the host.
Answer: ABC
14. Which of the following should engineers consider when troubleshooting the bandwidth bottleneck on the network side? (Multiple choice)
A. Front-end link bandwidth
B. Bandwidth supported by controllers
C. Back-end disk bandwidth
D. Bandwidth supported by iBMC
Answer: ABC
15. Which of the following methods can be used by engineers to obtain storage device performance data? (Multiple choice)
A. Logging in to the storage device and manually downloading the data
B. Downloading the data from the dump server
C. Obtaining the data through DeviceManager
D. Obtaining the data through SmartKit
Answer: ABD
16. If a storage system generates fault alarms, which methods can be used to collect fault information about the storage system? (Multiple choice)
A. Exporting system data
B. Checking all events
C. Checking alarm information
D. Checking zone configuration
Answer: ABC
Comments